Language
Products
The company is integrating of R&D,Production and Sales of Microbiology test.
/
/
/
MUG Test reagent(ID1804)Identification of Escherichia coli
Number of views:
1000

MUG Test reagent(ID1804)Identification of Escherichia coli

[product name] General name: gram negative bacilli identification reagent (mug test reagent) [package specification] 40 test / box [intended use] E. coli to species were identified by one test, O157 was negative, which can be used to screen O157, E. coli Mug positive; Incubation at 37 ℃ for 0.5 to 2 hours, during which blue and white fluorescence was observed. Indole positive. [storage conditions and validity period] Keep away from light, dry and airtight, store at 2 ℃ ~ 8 ℃, and the validity period is 12 months. See the details on the product package. [sample requirements] Logarithmic colonies, Gram-negative bacteria, shall conform to the colony characteristics, microscopic characteristics and other biochemical characteristics of the target bacteria. [inspection method] 1. Soak the filter paper at the end of the mug test strip with mug buffer; 2. Pick out the suspicious colony to be tested with the inoculation ring and smear it on the end filter paper; 3. Place in a closed container; Incubate at 35 ℃± 2 ℃ for 1.5h ~ 2H. During the incubation, observe whether there is blue fluorescence at the bacteria coated on the end of the test strip every half an hour or in time under long wave ultraviolet light (366nm, such as wood lamp).
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
(ID1804)
Specifications:
40 test / box
Quantity
-
+
Stock:
Product description
Parameters
[product name]
General name: gram negative bacilli identification reagent (mug test reagent)
[package specification]
40 test / box
[intended use]
E. coli to species were identified by one test, O157 was negative, which can be used to screen O157, E. coli Mug positive; Incubation at 37 ℃ for 0.5 to 2 hours, during which blue and white fluorescence was observed. Indole positive.
[storage conditions and validity period]
Keep away from light, dry and airtight, store at 2 ℃ ~ 8 ℃, and the validity period is 12 months. See the details on the product package.
[sample requirements]
Logarithmic colonies, Gram-negative bacteria, shall conform to the colony characteristics, microscopic characteristics and other biochemical characteristics of the target bacteria.
[inspection method]
1. Soak the filter paper at the end of the mug test strip with mug buffer;
2. Pick out the suspicious colony to be tested with the inoculation ring and smear it on the end filter paper;
3. Place in a closed container; Incubate at 35 ℃± 2 ℃ for 1.5h ~ 2H. During the incubation, observe whether there is blue fluorescence at the bacteria coated on the end of the test strip every half an hour or in time under long wave ultraviolet light (366nm, such as wood lamp).
 
1
 
Advertisement examination and approval No.: yyxgs (Wen) No. 2019050117
Keyword:
Test reagent
Identification of Escherichia coli
Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

底部版权

Time of issue:2021-06-28 17:52:44

TEL:+86-23-88613755  88613756 ADD:Chongqing Jiangbei District No. 48 Road, road, industrial park, No. 2, No.

© 2021 Chongqing Pang Tong Medical Devices Co., Ltd ICP:渝ICP备16005976号-1 Powered By: www.300.cn

Ustar